Dual-power nebulizer / (Record no. 3547)

MARC details
000 -LEADER
fixed length control field 02945nam a22003017a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250308030823.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 240601b ||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Language of cataloging English.
Transcribing agency CvSU-CCAT Campus Library.
Description conventions rda.
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number UM R 856
Item number D83 2010
245 ## - TITLE STATEMENT
Title Dual-power nebulizer /
Statement of responsibility, etc. Billy James M. Larios [and three others].
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Rosario, Cavite :
Name of publisher, distributor, etc. Cavite State University-CCAT Campus,
Date of publication, distribution, etc. 2010.
300 ## - PHYSICAL DESCRIPTION
Extent viii, 23 leaves :
Other physical details illustrations ;
Dimensions 28 cm
500 ## - GENERAL NOTE
General note Research Study (LSHS) -- Cavite State University-CCAT Campus, 2010.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references and appendices.
520 ## - SUMMARY, ETC.
Thesis Abstract <a href="Billy James M. Larios, Russel Luis H. Lomat, Raymund P. Pulido Jr., Cavite State University Rosario Campus, Science Education Laboratory High School "DUAL- POWER NEBULIZER".<br/><br/>Co-author/Adviser. Mrs. Remedios G. Lisondra<br/><br/>This feasibility study sought to design and construct a Dual- Power Nebulizer using locally available materials and manpower.<br/><br/>Specifically, this study attempted to:<br/><br/>1. design, construct, and revise a Dual- Power Nebulizer.<br/><br/>2. test the efficacy and acceptability of the Dual-Power Nebulizer.<br/><br/>The dual- power nebulizer was so designed and constructed to save money and to be used in time of emergencies especially during blackouts and in time of traveling. The device has an input voltage of twelve (12) volts with an output of two hundred twenty (220) volts. It can be charge using rechargeable batteries or electrical sources. The materials used gathered from junk/ scrap shop and if new resources are desired, same gadgets can be bought in the market. During the testing of Dual-Power Nebulizer, the researchers evaluated its efficacy by testing the time it took to dissolve the nebulae using the battery and electricity as the source of power. Initially, it was found out that improvised device did not last long since it was only functional for about twenty- one seconds so it underwent revision to improve its semiability. In addition; a new battery of 12 volts was used to replace the 6 volt cells. The battery can be charged within the span of three to five hours, the battery can last for two hours. Results of the study revealed that it is feasible to construct a Dual- Power Nebulizer because the design and construction are simple, supplies and materials are available in the local market. The total cost of the completed product is P 1126.50.">Billy James M. Larios, Russel Luis H. Lomat, Raymund P. Pulido Jr., Cavite State University Rosario Campus, Science Education Laboratory High School "DUAL- POWER NEBULIZER".<br/><br/>Co-author/Adviser. Mrs. Remedios G. Lisondra<br/><br/>This feasibility study sought to design and construct a Dual- Power Nebulizer using locally available materials and manpower.<br/><br/>Specifically, this study attempted to:<br/><br/>1. design, construct, and revise a Dual- Power Nebulizer.<br/><br/>2. test the efficacy and acceptability of the Dual-Power Nebulizer.<br/><br/>The dual- power nebulizer was so designed and constructed to save money and to be used in time of emergencies especially during blackouts and in time of traveling. The device has an input voltage of twelve (12) volts with an output of two hundred twenty (220) volts. It can be charge using rechargeable batteries or electrical sources. The materials used gathered from junk/ scrap shop and if new resources are desired, same gadgets can be bought in the market. During the testing of Dual-Power Nebulizer, the researchers evaluated its efficacy by testing the time it took to dissolve the nebulae using the battery and electricity as the source of power. Initially, it was found out that improvised device did not last long since it was only functional for about twenty- one seconds so it underwent revision to improve its semiability. In addition; a new battery of 12 volts was used to replace the 6 volt cells. The battery can be charged within the span of three to five hours, the battery can last for two hours. Results of the study revealed that it is feasible to construct a Dual- Power Nebulizer because the design and construction are simple, supplies and materials are available in the local market. The total cost of the completed product is P 1126.50.</a>
546 ## - LANGUAGE NOTE
Language note In English text.
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Dual-power nebulizer.
9 (RLIN) 15131
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Nebulizer construction.
9 (RLIN) 15132
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Health equipment innovation.
9 (RLIN) 15133
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Medical devices.
9 (RLIN) 15134
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Emergency use.
9 (RLIN) 15135
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Lomat, Russel Luis H., author.
9 (RLIN) 13270
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Pulido, Raymund P., author.
9 (RLIN) 13271
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Lisondra, Remedios R., adviser.
9 (RLIN) 13272
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Library of Congress Classification
Koha item type Thesis/Manuscripts/Dissertations
Classification part R 856 D83 2010
Call number prefix UM
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Shelving location Date acquired Coded location qualifier Full call number Barcode Date last seen Copy number Price effective from Koha item type
    Library of Congress Classification     Thesis/Manuscript/Dissertation Cavite State University - CCAT Campus Cavite State University - CCAT Campus TH 09/09/2010 UM UM R 856 D83 2010 T00051 10/24/2025 1 06/01/2024 Thesis/Manuscripts/Dissertations