Dual-power nebulizer / (Record no. 3547)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02945nam a22003017a 4500 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250308030823.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 240601b ||||| |||| 00| 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Language of cataloging | English. |
| Transcribing agency | CvSU-CCAT Campus Library. |
| Description conventions | rda. |
| 050 ## - LIBRARY OF CONGRESS CALL NUMBER | |
| Classification number | UM R 856 |
| Item number | D83 2010 |
| 245 ## - TITLE STATEMENT | |
| Title | Dual-power nebulizer / |
| Statement of responsibility, etc. | Billy James M. Larios [and three others]. |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Rosario, Cavite : |
| Name of publisher, distributor, etc. | Cavite State University-CCAT Campus, |
| Date of publication, distribution, etc. | 2010. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | viii, 23 leaves : |
| Other physical details | illustrations ; |
| Dimensions | 28 cm |
| 500 ## - GENERAL NOTE | |
| General note | Research Study (LSHS) -- Cavite State University-CCAT Campus, 2010. |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE | |
| Bibliography, etc. note | Includes bibliographical references and appendices. |
| 520 ## - SUMMARY, ETC. | |
| Thesis Abstract | <a href="Billy James M. Larios, Russel Luis H. Lomat, Raymund P. Pulido Jr., Cavite State University Rosario Campus, Science Education Laboratory High School "DUAL- POWER NEBULIZER".<br/><br/>Co-author/Adviser. Mrs. Remedios G. Lisondra<br/><br/>This feasibility study sought to design and construct a Dual- Power Nebulizer using locally available materials and manpower.<br/><br/>Specifically, this study attempted to:<br/><br/>1. design, construct, and revise a Dual- Power Nebulizer.<br/><br/>2. test the efficacy and acceptability of the Dual-Power Nebulizer.<br/><br/>The dual- power nebulizer was so designed and constructed to save money and to be used in time of emergencies especially during blackouts and in time of traveling. The device has an input voltage of twelve (12) volts with an output of two hundred twenty (220) volts. It can be charge using rechargeable batteries or electrical sources. The materials used gathered from junk/ scrap shop and if new resources are desired, same gadgets can be bought in the market. During the testing of Dual-Power Nebulizer, the researchers evaluated its efficacy by testing the time it took to dissolve the nebulae using the battery and electricity as the source of power. Initially, it was found out that improvised device did not last long since it was only functional for about twenty- one seconds so it underwent revision to improve its semiability. In addition; a new battery of 12 volts was used to replace the 6 volt cells. The battery can be charged within the span of three to five hours, the battery can last for two hours. Results of the study revealed that it is feasible to construct a Dual- Power Nebulizer because the design and construction are simple, supplies and materials are available in the local market. The total cost of the completed product is P 1126.50.">Billy James M. Larios, Russel Luis H. Lomat, Raymund P. Pulido Jr., Cavite State University Rosario Campus, Science Education Laboratory High School "DUAL- POWER NEBULIZER".<br/><br/>Co-author/Adviser. Mrs. Remedios G. Lisondra<br/><br/>This feasibility study sought to design and construct a Dual- Power Nebulizer using locally available materials and manpower.<br/><br/>Specifically, this study attempted to:<br/><br/>1. design, construct, and revise a Dual- Power Nebulizer.<br/><br/>2. test the efficacy and acceptability of the Dual-Power Nebulizer.<br/><br/>The dual- power nebulizer was so designed and constructed to save money and to be used in time of emergencies especially during blackouts and in time of traveling. The device has an input voltage of twelve (12) volts with an output of two hundred twenty (220) volts. It can be charge using rechargeable batteries or electrical sources. The materials used gathered from junk/ scrap shop and if new resources are desired, same gadgets can be bought in the market. During the testing of Dual-Power Nebulizer, the researchers evaluated its efficacy by testing the time it took to dissolve the nebulae using the battery and electricity as the source of power. Initially, it was found out that improvised device did not last long since it was only functional for about twenty- one seconds so it underwent revision to improve its semiability. In addition; a new battery of 12 volts was used to replace the 6 volt cells. The battery can be charged within the span of three to five hours, the battery can last for two hours. Results of the study revealed that it is feasible to construct a Dual- Power Nebulizer because the design and construction are simple, supplies and materials are available in the local market. The total cost of the completed product is P 1126.50.</a> |
| 546 ## - LANGUAGE NOTE | |
| Language note | In English text. |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Dual-power nebulizer. |
| 9 (RLIN) | 15131 |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Nebulizer construction. |
| 9 (RLIN) | 15132 |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Health equipment innovation. |
| 9 (RLIN) | 15133 |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Medical devices. |
| 9 (RLIN) | 15134 |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Emergency use. |
| 9 (RLIN) | 15135 |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Lomat, Russel Luis H., author. |
| 9 (RLIN) | 13270 |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Pulido, Raymund P., author. |
| 9 (RLIN) | 13271 |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Lisondra, Remedios R., adviser. |
| 9 (RLIN) | 13272 |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Library of Congress Classification |
| Koha item type | Thesis/Manuscripts/Dissertations |
| Classification part | R 856 D83 2010 |
| Call number prefix | UM |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Collection code | Home library | Current library | Shelving location | Date acquired | Coded location qualifier | Full call number | Barcode | Date last seen | Copy number | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Library of Congress Classification | Thesis/Manuscript/Dissertation | Cavite State University - CCAT Campus | Cavite State University - CCAT Campus | TH | 09/09/2010 | UM | UM R 856 D83 2010 | T00051 | 10/24/2025 | 1 | 06/01/2024 | Thesis/Manuscripts/Dissertations |