Three-phase generator synchronizing trainer / (Record no. 1601)

000 -LEADER
fixed length control field 02979nam a22003137a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20220615013418.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220420b ||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Language of cataloging English.
Transcribing agency CvSU-CCAT Campus Library.
Description conventions rda.
050 ## - LIBRARY OF CONGRESS CALL NUMBER
Classification number UM TK 2761
Item number L44 2019
245 ## - TITLE STATEMENT
Title Three-phase generator synchronizing trainer /
Statement of responsibility, etc. John Michael L. Legacion, [and three others]
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Rosario, Cavite :
Name of publisher, distributor, etc. Cavite State University-CCAT Campus,
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Extent xv, 50 leaves :
Other physical details illustrations ;
Dimensions 28 cm
500 ## - GENERAL NOTE
General note Undergraduate Project Design (BSEE)--Cavite State University-CCAT Campus, 2019.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references and appendices.
520 ## - SUMMARY, ETC.
Summary, etc. <a href="LEGACION, JOHN MICHAEL L., NIVIAR, MARVIN V., NUAL, CRISTOPHER R, TITO, LORRAINE A. Three-phase generator synchronizing trainer. Undergraduate Design Project. Bachelor of Science in Electrical Engineering. Cavite State University - Cavite College of Arts and Trades Campus, Rosario, Cavite. June 2019. Adviser: Engr. Alvin A Castro. Technical Critic: Prof. Noelle T. Legaspi. <br/><br/>The study was conducted from August 2018 to March 2019 to develop a three ­phase generator to grid synchronizing trainer Specifically this study aims to: 1. design and construct a trainer for synchronizing AC generator. lt focuses on synchronizing two alternators where an alternator will connect in parallel to the other alternator that is in live system of constant voltage and constant frequency. 2. test and evaluate the proposed trainer in terms of its functionality, construction, effectiveness, reliability and safety. Lastly, assess the trainer to comply with the electrical standards. The trainer was constructed with individual digital meters that are used to test alternators like short circuit test, open circuit test and de resistance test. Digital multi-meters were constructed to check the voltage magnitude and frequency of the incoming generator and bus generator. The system uses synchroscope to check the voltage difference, frequency difference, phase sequence and phase angle between the incoming generator and bus generator. A synchronizing switch is use to switch on or make contact between alternators and grid source when it completely meets the condition of synchronizing. The results of the evaluation revealed that the three-phase generator synchronizing trainer is feasible and reliable. ">LEGACION, JOHN MICHAEL L., NIVIAR, MARVIN V., NUAL, CRISTOPHER R, TITO, LORRAINE A. Three-phase generator synchronizing trainer. Undergraduate Design Project. Bachelor of Science in Electrical Engineering. Cavite State University - Cavite College of Arts and Trades Campus, Rosario, Cavite. June 2019. Adviser: Engr. Alvin A Castro. Technical Critic: Prof. Noelle T. Legaspi. <br/><br/>The study was conducted from August 2018 to March 2019 to develop a three ­phase generator to grid synchronizing trainer Specifically this study aims to: 1. design and construct a trainer for synchronizing AC generator. lt focuses on synchronizing two alternators where an alternator will connect in parallel to the other alternator that is in live system of constant voltage and constant frequency. 2. test and evaluate the proposed trainer in terms of its functionality, construction, effectiveness, reliability and safety. Lastly, assess the trainer to comply with the electrical standards. The trainer was constructed with individual digital meters that are used to test alternators like short circuit test, open circuit test and de resistance test. Digital multi-meters were constructed to check the voltage magnitude and frequency of the incoming generator and bus generator. The system uses synchroscope to check the voltage difference, frequency difference, phase sequence and phase angle between the incoming generator and bus generator. A synchronizing switch is use to switch on or make contact between alternators and grid source when it completely meets the condition of synchronizing. The results of the evaluation revealed that the three-phase generator synchronizing trainer is feasible and reliable. </a>
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric generator
General subdivision Alternating current.
9 (RLIN) 4798
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric generator
General subdivision Design and construction.
9 (RLIN) 4799
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Synchronous generator.
9 (RLIN) 4800
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric wiring.
9 (RLIN) 900
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Legacion, John Michael L., author
9 (RLIN) 4698
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Niviar, Marvin V., author
9 (RLIN) 5217
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Nual, Christopher B., author
9 (RLIN) 5218
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Tito, Lorraine A., author
9 (RLIN) 5219
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Castro, Alvin A., adviser
9 (RLIN) 4698
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Legaspi, Noelle T., critic
9 (RLIN) 4796
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Thesis/Manuscripts/Dissertations
Classification part TK 2761
Item part L44 2019
Call number prefix UM
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Permanent location Current location Shelving location Date acquired Total Checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
          Thesis/Manuscript/Dissertation Cavite State University - CCAT Campus Cavite State University - CCAT Campus TH 04/20/2022   UM TK 2761 L44 2019 T0005053 04/20/2022 1 copy 04/20/2022 Thesis/Manuscripts/Dissertations

Powered by Koha